VRV Alpha redefines Variable Refrigerant Volume (VRV) technology from Japan with a newly engineered single-module outdoor structure, VRT Smart II Control, 50%–200% connection ratio, IP55 lizard/dust-sealed PCB box, and uninterrupted cooling up to 52°C ambient. Executed turnkey across Hyderabad by Versatile Air Conditioner Systems (CH. SANTHOSH).
Click through the 5 technical pillars below to inspect the complete architecture, hardware specifications, and official engineering slides of Daikin VRV Alpha.
Up to the 26 HP class (22, 24, 26 HP), Daikin VRV Alpha is now housed in a single compact outdoor module rather than twin combined units—reducing rooftop and service-balcony footprint by 7%.
1,750 mm × 765 mm) compared to 1.44 m² (1,880 mm × 765 mm) in conventional twin models.| Parameter | Conventional Models | New VRV Alpha Series |
| Casing Configuration | Twin Module | Large Single Module |
| Width × Depth | 1,880 × 765 mm | 1,750 × 765 mm |
| Installation Area | 1.44 m² | 1.34 m² (7% Less Space) |
Energy savings during actual part-load operation have been significantly elevated through coordinated hardware and software engineering:
VRV Alpha supports simultaneous extension of vertical height difference (upgraded from 90 m to 110 m) and equivalent piping length (up to 190 m), making it ideal for high-rise commercial buildings and sprawling luxury villas.
FXDQ, FXMQ-PB, and FXAQ indoor units.KHRP26M22H/33H/72H/73H).| Outdoor Unit Class | FXDQ / FXMQ-PB / FXAQ | Other VRV IDUs* |
| Single ODU (6–20 HP) | 200% | 200% |
| Single ODU (22–24 HP) | 200% | 180% |
| Single ODU (26 HP) | 200% | 160% |
| Double Outdoor Units | 200% | 160% |
| Triple Outdoor Units | 200% | 130% |
VRV Alpha eliminates manual refrigerant charging errors and speeds up project handover with automated self-diagnostics:
00P – 99P): Alternates step codes (t01 to t10) with real-time 0% to 99% completion percentage.
Engineered for uninterrupted operation in Hyderabad's peak summer heat and dusty outdoor conditions:
Explore the 4 integrated building blocks of a Daikin VRV Alpha installation with direct access to the official 2026 engineering catalogue.
Thoughtfully designed to complement every interior—from sleek 360° Round Flow Ceiling Cassettes (with motion & floor sensors), Slim Ceiling Concealed Ducted units (FXDQ / FXMQ-PB), and compact corner types to high-wall FXAQ units. Uniform airflow, whisper-quiet operation down to 25 dBA, and VRT Smart demand tracking.
View IDU Catalogue (Page 53) →Features a newly engineered single-module structure up to 26 HP and multi-module combinations up to 60 HP. Equipped with 4D Inverter Scroll Compressors, Subcooling Plate Heat Exchangers, IP55 sealed PCB enclosures, and anti-corrosion blue-fin coils for long-term durability.
View ODU Catalogue (Page 66) →Intelligent, centralized management for projects of every scale—from individual villa zones via smartphone app and stylish wired BRC1E remotes to large commercial buildings using Intelligent Touch Manager (iTM), BACnet/LonWorks BMS gateways, and power proportional distribution billing.
View Controls Catalogue (Page 82) →Delivers energy-saving fresh air ventilation by seamlessly interlocking with VRV Alpha indoor units. By recovering heat and moisture from exhaust air via a high-efficiency enthalpy paper core, HRV reduces air conditioning cooling load by ~20% while maintaining healthy indoor air quality.
View HRV Catalogue (Page 118) →Estimate the required VRV system capacity (HP & TR), connectable indoor units, and turnkey project investment for your Villa, Office, Hospital, or Showroom in Hyderabad.
Compare outdoor module capacities, crossed-out MRPs, and VACS project offer prices:
A VRV system is only as reliable as its copper piping, REFNET brazing, and vacuum commissioning. Under the direct technical supervision of CH. SANTHOSH, every VRV project follows Daikin Japan's strict installation standards:
Room-by-room thermal load analysis considering glazing, orientation, occupancy, and simultaneity factor (50%–200% connection ratio).
Selection of exact copper pipe diameters, REFNET Y-joints/headers, condensate drain slopes, and ceiling diffuser placements aligned with your architect's false-ceiling plan.
Continuous dry-nitrogen purging during copper & REFNET joint brazing to prevent internal carbon scale formation that could clog electronic expansion valves (EEVs).
24 to 48-hour high-pressure nitrogen holding test across the entire refrigerant network prior to false-ceiling closure to guarantee 100% zero leaks.
Two-stage vacuum pump evacuation below 500 microns to remove all moisture, followed by Daikin VRV Alpha's automated refrigerant charging.
Full t01–t10 (0–99%) automated commissioning verification, CFM balancing, client handover training, and priority post-installation AMC support.